Gram BioPlus freezers

Gram BioPlus freezers are professional laboratory freezers designed for the safe storage of temperature-sensitive samples, reagents and pharmaceutical products at sub-zero temperatures. These freezers are engineered for applications where temperature stability, reliability and continuous operation are essential.

BioPlus freezers are part of the Gram BioLine range and offer a broad selection of configurations, from standard laboratory freezers to low temperature freezers. Thanks to multiple volumes, cabinet formats and door types, the correct solution can be selected for each laboratory application.

Request expert advice

This product group is part of the category Laboratory freezers and belongs to the Gram Bioline range.

Search results

[Zoekresultaat Tekst]

Not sure which product fits your needs or 
want to be certain about your choice? 
Request free advice 

[Zoeken - geen resultaten gevonden]

No results found

Did you mean: {{suggestion.Description}} , ?
Search term: {{webshop.searchValue}}
Filters: Clear all filters {{filter.key}}: {{filter.filter}}
{{webshop.totalItems | number}} {{'Items' | lowercase}}
Productcode:
Found in
Price
Quantity
Price per unit
{{itemRebate.AmountStart}} {{itemRebate.AmountStart < itemRebate.AmountEnd ? " - " + itemRebate.AmountEnd : " + "}}
 
Sale
New
{{item.Description}} {{item.Description}} {{item.Description}}

Productcode:
Found in
Price
Quantity
Price per unit
{{itemRebate.AmountStart}} {{itemRebate.AmountStart < itemRebate.AmountEnd ? " - " + itemRebate.AmountEnd : " + "}}

[Niet ingelogd - Login om uw prijzen te zien]

(log in or create an account to see your prices)

 

Ask a question

Configure
[Zoekresultaat Tekst]

Not sure which product fits your needs or 
want to be certain about your choice? 
Request free advice 

Key features of Gram BioPlus freezers

  • Temperature ranges from approximately −25 °C to −5 °C and −35 °C to −5 °C
  • Stable and uniform temperature distribution
  • Professional alarm system with visual and audible alerts
  • Potential-free alarm contact for external monitoring
  • Suitable for GMP, GLP and pharmaceutical environments
  • Available in multiple volumes and cabinet configurations

Difference between RF and EF BioPlus freezers

  • RF models – laboratory freezers with a temperature range of approximately −25 °C to −5 °C, suitable for general laboratory and pharmaceutical applications
  • EF models – low temperature freezers with a temperature range of approximately −35 °C to −5 °C, suitable when lower storage temperatures are required

Applications

  • Storage of reagents, media and samples
  • Pharmaceutical and clinical storage
  • Biotechnological and microbiological research
  • QC and QA laboratories
  • Research institutes and hospitals

How are Gram BioPlus product codes structured?

Each Gram BioPlus freezer is assigned a product code that provides insight into the freezer type and configuration:

  • RF – Laboratory freezer (−25 °C to −5 °C)
  • EF – Low temperature freezer (−35 °C to −5 °C)
  • Number (500, 600, 660, 930, 1270, 1400) – Net storage volume
  • D – Deep cabinet (extra depth)
  • W – Wide cabinet (wider design)
  • C – Glass door
  • L – Solid door

Example: BioPlus RF660WC is a BioPlus laboratory freezer with a temperature range down to approximately −25 °C, a net capacity of around 660 litres, a wide cabinet configuration and a glass door.

Available Gram BioPlus freezer models

EF models (−35 °C to −5 °C)
  • BioPlus EF600W-35ºCC – glass door
  • BioPlus EF600W-35ºCL – solid door
  • BioPlus EF660W-35ºCC – glass door
  • BioPlus EF660W-35ºCL – solid door
RF models (−25 °C to −5 °C)
RF 500
  • BioPlus RF500C – glass door
  • BioPlus RF500L – solid door
RF 600 – Deep cabinet
  • BioPlus RF600DC – glass door
  • BioPlus RF600DL – solid door
RF 600 – Wide cabinet
  • BioPlus RF600WC – glass door
  • BioPlus RF600WL – solid door
RF 660 – Deep cabinet
  • BioPlus RF660DC – glass door
  • BioPlus RF660DL – solid door
RF 660 – Wide cabinet
  • BioPlus RF660WC – glass door
  • BioPlus RF660WL – solid door
RF 930
  • BioPlus RF930C – glass door
  • BioPlus RF930L – solid door
RF 1270
  • BioPlus RF1270C – glass door
  • BioPlus RF1270L – solid door
RF 1400
  • BioPlus RF1400C – glass door
  • BioPlus RF1400L – solid door

Frequently asked questions

When should I choose an EF freezer instead of an RF freezer?

Choose an EF freezer when storage at lower temperatures down to approximately −35 °C is required. For standard laboratory applications down to approximately −25 °C, an RF freezer is sufficient.

Which BioPlus freezer is best suited for my application?

The right choice depends on the required temperature range, storage volume and available space. Our specialists are happy to assist you in selecting the most suitable BioPlus freezer.

Request expert advice

Call me back
{{error}}
Name* is required.
Name* is invalid
Phone number* is required.
Phone number* is invalid
Email address* is required.
Email address* is invalid
Question or details (optional) is invalid
Submitting the form is not possible due to the reCAPTCHA check.
ReCaptcha is required.
ReCaptcha is invalid
Send is invalid
×
{{successMessage}}
×
{{errorMessage}}